CVE-2026-58114CriticalAmericas

Siemens SIMATIC

View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recom...

Siemens SIMATIC
Image:RELIABLIXSHIELD — site-designed thumbnail
Primary Advisory
CISA Advisories
Published Date
Nov 17, 2026
Region Scope
Americas

Campaign Analysis

View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC are affected: SIMATIC BATCH V9.1 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2020 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2022 vers:all/* (CVE-2026-58114) SIMATIC PCS 7 V9.1 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2020 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2022 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V17 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V18 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V19 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V20 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V21 vers:all/* (CVE-2026-58114) SIMATIC WinCC V7.5 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.0 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.1 vers:all/* (CVE-2026-58114) CVSS Vendor Equipment v3 7.5 Siemens SIMATIC BATCH V9.1 1 Vulnerability Weak Authentication Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-58114 Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC. Read More 14 Affected Products SIMATIC BATCH V9.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC WinCC Runtime Professional V20 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC Runtime Professional V21 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V7.5 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V8.0 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V8.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC Information Server 2020 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC Information Server 2022 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC PCS 7 V9.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC Process Historian 2020 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC Process Historian 2022 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC WinCC Runtime Professional V17 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC Runtime Professional V18 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC Runtime Professional V19 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available Additional Metrics Relevant CWE: CWE-1390 Weak Authentication CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-970803 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-970803 advisory Legal Notice and Terms of Use

Source Advisory

Official joint cybersecurity advisory published by CISA Advisories:

https://www.cisa.gov/news-events/ics-advisories/icsa-26-321-08 →
ShareShare on X →Share on LinkedIn →

Continue Reading

CriticalGlobal ThreatAmericas
CISA Adds 10 Known Exploited Vulnerabilities to Catalog
Image:RELIABLIXSHIELD — site-designed thumbnail

CISA Adds 10 Known Exploited Vulnerabilities to Catalog

CISA has added 10 new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog , based on evidence of active exploitation. CVE-2023-25914 Danfoss AK-SM 800A Series Path Traversal Vulnerability CVE-2023-25915 Danfoss AK-SM 800A Series Improper Input Validation Vulne...

CISA AdvisoriesRead brief →
CriticalGlobal ThreatAmericas
AutomationDirect C-More EA9 Programming Software
Image:RELIABLIXSHIELD — site-designed thumbnail

AutomationDirect C-More EA9 Programming Software

View CSAF Summary Successful exploitation of this vulnerability could allow attackers to corrupt application memory and cause instability or a crash, potentially leading to arbitrary code execution, if a user is convinced to open a malicious file. The following versions of Aut...

CISA AdvisoriesRead brief →
CriticalGlobal ThreatAmericas
CISA Adds Three Known Exploited Vulnerabilities to Catalog
Image:RELIABLIXSHIELD — site-designed thumbnail

CISA Adds Three Known Exploited Vulnerabilities to Catalog

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog , based on evidence of active exploitation. CVE-2026-131914 Idunno AntiCsrf Deserialization of Untrusted Data Vulnerability CVE-2026-132165 Drupal Core Remote Code Execution Vulnerabi...

CISA AdvisoriesRead brief →