Intelligence Discovery

67 matching items

Search All Intelligence

Search across titles, summaries, full article bodies, CVE identifiers, and advisory numbers, and refine results by type, region, severity, or date range.

Reset filters

Filters sync to URL parameters for shareable views.

Showing 51–60 of 67 records · Sorted newest first

Page 6 / 7
CriticalGlobal ThreatAmericas
CVE-2026-112136
Siemens Mendix Studio Pro
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens Mendix Studio Pro

View CSAF Summary Mendix Studio Pro contains multiple vulnerabilities in the MCP Server, that could allow an attacker with network access to interact with the server remotely or trick a user's browser into sending unauthorized requests, potentially leading to unauthorized data...

View CSAF Summary Mendix Studio Pro contains multiple vulnerabilities in the MCP Server, that could allow an attacker with network access to interact with the server remotely or trick a user's browser into sending unauthorized requests, potentially leading to unauthorized data access, tool execution, or system compromise. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Mendix Studio Pro are affected: Mendix Studio Pro 11 vers:intdot/>=11.15.0|<11.16.0 (CVE-2026-112136, CVE-2026-112137) Mendix Studio Pro 11.12 vers:intdot/>=11.12.6|<11.12.7 (CVE-2026-112136, CVE-2026-112137) CVSS Vendor Equipment v3 8.8 Siemens Mendix Studio Pro 11 2 Vulnerabilities Binding to an Unrestricted IP Address, Cross-Site Request Forgery (CSRF) Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-112136 The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely. Read More 2 Affected Products Mendix Studio Pro 11 >= V11.15.0 < V11.16.0 Product Status: known_affected Remediations Mitigation Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules. Vendor fix Update to V11.16.0 or later version Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7 Product Status: known_affected Remediations Mitigation Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules. Vendor fix Update to V11.12.7 or later version Additional Metrics Relevant CWE: CWE-1327 Binding to an Unrestricted IP Address CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H View CVE Details CVE-2026-112137 The affected products MCP Server does not properly validate Content-Type and Origin headers on incoming HTTP requests, leaving it vulnerable to Cross-Site Request Forgery (CSRF). This could allow a malicious web page to trick a user's browser into sending unauthorized requests and executing unintended actions on the local MCP Server. Read More 4 Affected Products Mendix Studio Pro 11 >= V11.15.0 < V11.16.0 Product Status: known_affected Remediations Mitigation Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1). Vendor fix Update to V11.16.0 or later version Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7 Product Status: known_affected Remediations Mitigation Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1). Vendor fix Update to V11.12.7 or later version Mendix Studio Pro 11 >= V11.15.0 < V11.16.0 Product Status: known_affected Remediations Mitigation Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1). Vendor fix Update to V11.16.0 or later version Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7 Product Status: known_affected Remediations Mitigation Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1). Vendor fix Update to V11.12.7 or later version Additional Metrics Relevant CWE: CWE-352 Cross-Site Request Forgery (CSRF) CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:L View CVE Details Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-710379 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-16 2 Mapped the advisory to Mendix products to be present on the Mendix Atom Feed 2026-11-17 3 Initial CISA Republication of Siemens ProductCERT SSA-710379 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatAmericas
CVE-2026-85114
Siemens .NET Client Library for SIMATIC S7 Webserver API
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens .NET Client Library for SIMATIC S7 Webserver API

View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Clien...

View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens .NET Client Library for SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/<3.3.61, vers:intdot/<3.3.62 (CVE-2026-85114, CVE-2026-85115) CVSS Vendor Equipment v3 7.5 Siemens .NET Client Library for SIMATIC S7 Webserver API 2 Vulnerabilities Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Generation of Error Message Containing Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-85114 Affected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application. Read More 1 Affected Product .NET Client Library for SIMATIC S7 Webserver API < V3.3.61 Product Status: known_affected Remediations Vendor fix Update to V3.3.61 or later version Additional Metrics Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N View CVE Details CVE-2026-85115 Affected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC. Read More 2 Affected Products .NET Client Library for SIMATIC S7 Webserver API < V3.3.61 Product Status: known_affected Remediations .NET Client Library for SIMATIC S7 Webserver API < V3.3.62 Product Status: known_affected Remediations Vendor fix Update to V3.3.62 or later version Additional Metrics Relevant CWE: CWE-209 Generation of Error Message Containing Sensitive Information CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N View CVE Details Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-390352 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-10-13 Date Revision Summary 2026-10-13 1 Publication Date 2026-11-10 2 Added researcher acknowledgement 2026-11-17 3 Initial CISA Republication of Siemens ProductCERT SSA-390352 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatAmericas
CVE-2026-114938
Critical Java Vulnerability Requires Immediate Patching
Image:RELIABLIXSHIELD — site-designed thumbnail

Critical Java Vulnerability Requires Immediate Patching

Purpose CISA strongly urges organizations to immediately patch the recently disclosed Oracle Java vulnerability CVE-2026-114938 . This critical memory-corruption vulnerability, known as “Java4Shell,” affects the Base64 decoder of the x86-64 HotSpot Java Virtual Machine (JVM),...

Purpose CISA strongly urges organizations to immediately patch the recently disclosed Oracle Java vulnerability CVE-2026-114938 . This critical memory-corruption vulnerability, known as “Java4Shell,” affects the Base64 decoder of the x86-64 HotSpot Java Virtual Machine (JVM), which is part of the Java Development Kit (JDK). Specially crafted Base64 input could crash the JVM and allow for unauthenticated remote code execution. Actions to take CISA urges organizations to take the following actions: Identify affected Java installations. Review your software inventory for JDKs and Java runtimes, including those bundled with third-party applications or included in container images and appliances. Note: JDKs and Java runtimes may not appear as separate entries in software inventories. Apply relevant Java and vendor patches as soon as they are available, prioritizing internet-facing systems. If immediate patching is not feasible, implement temporary compensating controls, such as restricting and validating Base64 input at the application boundary, enforcing input-size limits, and limiting unauthenticated access. Review Oracle’s security advisory for guidance on patching and affected products and versions. Monitor for indicators of suspicious activity, including rogue runtimes, unexpected JVM crashes, and suspicious Java processes. Resources CISA urges network defenders to review the following resource and apply necessary updates: Vendor Guidance Oracle’s Security Advisory: Critical Security Patch Update – November 2026 Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Acknowledgements The Canadian Centre for Cyber Security (Cyber Centre) contributed to this Alert.

CriticalGlobal ThreatAmericas
CVE-2026-109830
Siemens meta-iot2050
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens meta-iot2050

View CSAF Summary meta-iot2050 (https://github.com/siemens/meta-iot2050) from V01.03.01 contains a Command Injection vulnerability in the firmware update tool that could allow an attacker which is able to manipulate a configuration file to have arbitrary commands run as root....

View CSAF Summary meta-iot2050 (https://github.com/siemens/meta-iot2050) from V01.03.01 contains a Command Injection vulnerability in the firmware update tool that could allow an attacker which is able to manipulate a configuration file to have arbitrary commands run as root. Siemens is preparing fixes and recommends mitigations for products where fixes are not or not yet available. The following versions of Siemens meta-iot2050 are affected: meta-iot2050 vers:intdot/>=01.03.01 (CVE-2026-109830) CVSS Vendor Equipment v3 7.3 Siemens meta-iot2050 1 Vulnerability Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-109830 Affected devices take parts from a configuration file and execute them unchecked. This could allow an attacker which is able to manipulate the configuration file to make the user execute arbitrary code on the device. Read More 1 Affected Product meta-iot2050 >= V01.03.01 Product Status: known_affected Remediations None available Currently no fix is available Additional Metrics Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-724261 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-724261 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatAmericas
CVE-2026-64629
Siemens Simcenter Femap
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens Simcenter Femap

View CSAF Summary Simcenter Femap is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for...

View CSAF Summary Simcenter Femap is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version. The following versions of Siemens Simcenter Femap are affected: Simcenter Femap vers:intdot/<2606.0002 (CVE-2026-64629) CVSS Vendor Equipment v3 7.8 Siemens Simcenter Femap 1 Vulnerability Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-64629 The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Read More 1 Affected Product Simcenter Femap < V2606.0002 Product Status: known_affected Remediations Vendor fix Update to V2606.0002 or later version Additional Metrics Relevant CWE: CWE-125 Out-of-bounds Read CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-105852 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-105852 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatAmericas
CVE-2026-109097
Siemens ROS#
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens ROS#

View CSAF Summary ROS# before version 2.3.1 contains a code injection vulnerability that could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Siemens has released a new version for ROS#...

View CSAF Summary ROS# before version 2.3.1 contains a code injection vulnerability that could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Siemens has released a new version for ROS# and recommends to update to the latest version. The following versions of Siemens ROS# are affected: ROS# vers:intdot/<2.3.1 (CVE-2026-109097) CVSS Vendor Equipment v3 8.2 Siemens ROS# 1 Vulnerability Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-109097 Affected systems do not properly escape text of message definition files. This could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Read More 1 Affected Product ROS# < V2.3.1 Product Status: known_affected Remediations Vendor fix Update to V2.3.1 or later version Additional Metrics Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-435267 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-435267 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatAmericas
CVE-2026-58114
Siemens SIMATIC
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens SIMATIC

View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recom...

View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC are affected: SIMATIC BATCH V9.1 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2020 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2022 vers:all/* (CVE-2026-58114) SIMATIC PCS 7 V9.1 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2020 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2022 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V17 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V18 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V19 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V20 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V21 vers:all/* (CVE-2026-58114) SIMATIC WinCC V7.5 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.0 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.1 vers:all/* (CVE-2026-58114) CVSS Vendor Equipment v3 7.5 Siemens SIMATIC BATCH V9.1 1 Vulnerability Weak Authentication Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-58114 Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC. Read More 14 Affected Products SIMATIC BATCH V9.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC WinCC Runtime Professional V20 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC Runtime Professional V21 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V7.5 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V8.0 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V8.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC Information Server 2020 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC Information Server 2022 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC PCS 7 V9.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC Process Historian 2020 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC Process Historian 2022 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC WinCC Runtime Professional V17 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC Runtime Professional V18 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC Runtime Professional V19 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available Additional Metrics Relevant CWE: CWE-1390 Weak Authentication CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-970803 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-970803 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatAmericas
CVE-2026-106175
Siemens RUGGEDCOM APE1808
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens RUGGEDCOM APE1808

View CSAF Summary Fortinet has published information on a Double Free vulnerability in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to update Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Con...

View CSAF Summary Fortinet has published information on a Double Free vulnerability in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to update Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-106175) CVSS Vendor Equipment v3 2.3 Siemens RUGGEDCOM APE1808 1 Vulnerability Double Free Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-106175 A Double Free vulnerability [CWE-415] in FortiOS, FortiProxy and FortiSwitch may allow a local authenticated attacker to crash the newcli daemon via crafted CLI commands. Read More 1 Affected Product RUGGEDCOM APE1808 with Fortinet NGFW Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information Additional Metrics Relevant CWE: CWE-415 Double Free CVSS Version Base Score Base Severity Vector String 3.1 2.3 LOW CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-651988 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-651988 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatAmericas
CVE-2026-59082
Siemens SIMATIC WinCC
Image:RELIABLIXSHIELD — site-designed thumbnail

Siemens SIMATIC WinCC

View CSAF Summary Graphics Designer of SIMATIC WinCC before V8.2 contains an implicit active content execution vulnerability upon opening files, which could allow an attacker to cause arbitrary code execution on the device. Siemens is preparing fixes and recommends specific mi...

View CSAF Summary Graphics Designer of SIMATIC WinCC before V8.2 contains an implicit active content execution vulnerability upon opening files, which could allow an attacker to cause arbitrary code execution on the device. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC WinCC are affected: SIMATIC WinCC V7.5 vers:all/* (CVE-2026-59082) SIMATIC WinCC V8.0 vers:all/* (CVE-2026-59082) SIMATIC WinCC V8.1 vers:all/* (CVE-2026-59082) CVSS Vendor Equipment v3 7.8 Siemens SIMATIC WinCC V7.5 1 Vulnerability Insufficient UI Warning of Dangerous Operations Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-59082 Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device. Read More 3 Affected Products SIMATIC WinCC V7.5 Product Status: known_affected Remediations Mitigation The affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product. Also make sure to only open files from trusted sources. None available Currently no fix is available SIMATIC WinCC V8.0 Product Status: known_affected Remediations Mitigation The affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product. Also make sure to only open files from trusted sources. None available Currently no fix is available SIMATIC WinCC V8.1 Product Status: known_affected Remediations Mitigation The affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product. Also make sure to only open files from trusted sources. None available Currently no fix is available Additional Metrics Relevant CWE: CWE-357 Insufficient UI Warning of Dangerous Operations CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-979641 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-979641 advisory Legal Notice and Terms of Use

CriticalGlobal ThreatGlobal
AA25-203A
#StopRansomware: Interlock Double-Extortion Ransomware Campaign
Image:RELIABLIXSHIELD — site-designed thumbnail

#StopRansomware: Interlock Double-Extortion Ransomware Campaign

Actor / Campaign: Interlock ransomware actors

Joint CISA and FBI advisory detailing Interlock ransomware operations targeting commercial enterprises and critical infrastructure across North America and Europe.

First observed in September 2024, Interlock threat actors employ drive-by compromise and ClickFix-style social engineering lures—including fake browser updates and CAPTCHA prompts—to deploy remote access trojans and credential stealers before encrypting Windows and Linux virtualized environments.

Source: CISA / FBI / HHS / MS-ISAC Advisory AA25-203A
Search Intelligence | RELIABLIXSHIELD News